Specification:

Descriptions of Omron G9SB-3012-C AC/DC24 provided by its distributors.

SAFETY RELAY UNIT, 3PST NO CATEGORY 4, SPST NC AUX, 5A, 2 CHANNEL INPUT, MANUAL RESET
Relay; 3PST; NO; G9SB-3012-C AC/DC24
Device Type = Safety Relay / Auxiliary Contact Configuration = 1NC / Contact Configuration without Delay = 3NO / Supply Voltage – AC V = 24 / Supply Voltage – DC V = 24 / Switching Current – AC A = 5 / Response Time ms = 10 / Termination Type = Screw Terminal / Mounting Type = DIN Rail Mount / Service Life – Mechanical = 5 Million Cycles / Service Life – Electric = 100000 Cycles / Series = G9SB Series

 

Safety Relay Unit G9SB Specifications

Main Contact Auxiliary Contact Number of Input Channels Reset Mode Input Type Rated Voltage Format
2 a None 2 ch Auto Inverse 24 V AC/DC Model G9SB-2002-A
1 ch, 2 ch Positive Common Model G9SB-200-B
2 ch Manual Inverse Model G9SB-2002-C
1 ch, 2 ch Positive Common Model G9SB-200-D
3 a 1 b No (Power supply directly OFF) Auto 24 V DC Model G9SB-3010
2 ch Inverse 24 V AC/DC Model G9SB-3012-A
1 ch, 2 ch Positive Common Model G9SB-301-B
2 ch Manual Inverse Model G9SB-3012-C
1 ch, 2 ch Positive Common Model G9SB-301-D
  • The inverse input type is mainly used for mechanical switch 2-ch input.
  • The positive common input type is mainly used for safety sensor input or for mechanical switch 1-ch input.
  • *The Model G9SB-3010 can be applied to safety category 3 because of its power supply double break.

Rating

Format Model G9SA-301 Model G9SA-501 Model G9SA-321-T□
Power Supply Voltage 24 V AC/DC: 24 V AC, 50/60 Hz / 24 V DC, 100 to 240 V AC: 100 to 240 V AC, 50/60 Hz
Allowable Voltage Fluctuation Range Power supply voltage -15% +10%
Power Consumption 24 V AC/DC: 1.8 VA/1.7 W max.
100 to 240 V AC: 9 VA max.
24 V AC/DC: 2.8 VA/2.6 W max.
100 to 240 V AC: 11 VA max.
24 V AC/DC: 3.5 VA/3.3 W max.
100 to 240 V AC: 12.5 VA max.

Power supply: G9SA type

  • *Increases by a maximum of 2 VA / 2 W when an expansion unit is connected.
Format Model G9SB-200□-□ Model G9SB-3010 Model G9SB-301□-□
Power Supply Voltage 24 V AC/DC: 24 V AC, 50/60 Hz / 24 DC, 24 V DC: 24 V DC
Allowable Voltage Fluctuation Range Power supply voltage -15% +10%
Power Consumption 1.6 VA / 1.4 W max. 1.7 W max. 2.0 VA / 1.7 W max.

Power supply: G9SB type

Format Model G9SA-301/321-T□ Model G9SA-501
Input Current 40 mA max. 60 mA max.

Input: G9SA type

  • *Increases by a maximum of 30 mA when an expansion unit is connected.
Format Model G9SB-200□-□ Model G9SA-3010 Model G9SB-301□-□
Input Current 25 mA max. 60 mA max. 30 mA max.

Input: G9SB type

Format Model G9SA-301/501/321-T□
Load Resistive Load
Rated Load 250 V AC 5 A, 30 V DC 5 A
Rated Carry Current 5 A

Switch: G9SA type

Format Model G9SB-200□-□, Model G9SB-3010, Model G9SB-301□-□
Load Resistive Load
Rated Load 250 V AC 5 A, 30 V DC 5 A
Rated Carry Current 5 A

Switch: G9SB type

Performance

Format Model G9SA-301 Model G9SA-501/321-T□
Contact Resistance 100 mΩ
Operating Time 30 ms max.
Response Time 10 ms max.
Insulation Resistance 100 MΩ min., 500 V DC ohmmeter
Dielectric Strength Between Different Outputs 2,500 V AC 50/60 Hz 1 min
Between Input and Output
Between Power Supply and Output
Between Power Supply and Input (100 to 240 V AC only)
Vibration Resistance 10 to 55 to 10 Hz, 0.375-mm single amplitude (0.75-mm double amplitude)
Shock Resistance Durability 300 m/s2
Malfunction 100 m/s2
Durability Mechanical 5,000,000 operations min. (at approx. 7,200 operations/hr)
Electrical 100,000 operations min. (at 1,800 operations/hr under rated load)
Failure Rate (P Level) (Reference Value) 5 V DC 1 mA
Ambient Operating Temperature -25 to +55°C (assuming no icing or condensation)
Ambient Operating Humidity 35 to 85% RH
Terminal Tightening Torque 0.98 N·m
Weight Approx. 210 g Approx. 270 g
  • Measured with 1 A at 5 V DC using the voltage-drop method.
  • Not Including bounce time.
  • The response time is the time it takes for the main contact to open after the input is turned OFF. Includes bounce time.
  • Measured with a 500 V DC ohmmeter at the same places that the dielectric strength was checked.
  • The durability is for an ambient temperature of 15 to 35°C and an ambient humidity of 25% to 75%.
  • The weight shown is for 24-VAC/VDC type. For 100 to 240-VAC type, add approximately 20 g.
Format Model G9SB-200□-□ Model G9SB-3010 Model G9SB-301□-□
Contact Resistance 100 mΩ
Operating Time 30 ms max.
Response Time 10 ms max.
Insulation Resistance 100 MΩ min., 500 V DC ohmmeter
Dielectric Strength Between Different Outputs 2,500 V AC 50/60 Hz 1 min
Between Input and Output
Between Power Supply and Output
Vibration Resistance 10 to 55 to 10 Hz, 0.375-mm single amplitude (0.75-mm double amplitude)
Shock Resistance Durability 300 m/s2
Malfunction 100 m/s2
Durability Mechanical 5,000,000 operations min. (at approx. 7,200 operations/hr)
Electrical 100,000 operations min. (at 1,800 operations/hr under rated load)
Failure Rate (P Level) (Reference Value) 5 V DC 1 mA
Ambient Operating Temperature -25 to +55°C (assuming no icing or condensation)
Ambient Operating Humidity 35 to 85% RH
Terminal Tightening Torque 0.5 N·m
Weight Approx. 115 g Approx. 135 g Approx. 120 g
  • Measured with 1 A at 5 V DC using the voltage-drop method.
  • Not Including bounce time.
  • The response time is the time it takes for the main contact to open after the input is turned OFF. Includes bounce time.
  • Measured with a 500 V DC ohmmeter at the same places that the dielectric strength was checked.
  • The durability is for an ambient temperature of 15 to 35°C and an ambient humidity of 25% to 75%.

“m-h3–wysiwyg”>Product dimensional outline drawings

Units: mm

Model G9SA-301, Model G9SA-501, Model G9SA-321-T□ full view

Model G9SA-301
Model G9SA-501
Model G9SA-321-T□ full view

Model G9SA-301, Model G9SA-501, Model G9SA-321-T□ dimensional outline drawing

Dimensional outline drawings

  • Time switch is only available for the Model G9SA-321-T□.
  • The K1 to K4 LEDs light when the a contacts of internal relays K1 to K4 close.
  • *Do not remove unless an expansion unit is being used.

Units: mm

Model G9SB-200□-□, Model G9SB-3010 full view

Model G9SB-200□-□
Model G9SB-3010 full view

Model G9SB-200□-□, Model G9SB-3010 dimensional outline drawing

Dimensional outline drawings

Units: mm

Model G9SB-301□-□ full view

Model G9SB-301□-□ full view

Model G9SB-301□-□ dimensional outline drawing

Dimensional outline drawings

Basic Information

 

 

Bình luận

Không có bình luận

Trả lời

Email của bạn sẽ không được hiển thị công khai. Các trường bắt buộc được đánh dấu *

Đối tác

Pre
  • Delta Logo
  • mitsubishi
  • OMRON
  • KEYENCE
  • PANASONIC
  • HIWIN
  • TBI
  • SIEMEN
  • ABB
  • FANUC
  • CNC
Next
Scroll left
Scroll right